EXPERIMENTAL RESULTS AND ANALYSIS ON UNBALANCED REGIMES ON A WYE-DELTA TRANSFORMER - EMERG
Logo EMERG

EXPERIMENTAL RESULTS AND ANALYSIS ON UNBALANCED REGIMES ON A WYE-DELTA TRANSFORMER

Volume XI, Issue 2/2025, pp 150 – 165, DOI:10.37410/EMERG.2025.2.10
Andreea IANȚOC, Mihai SĂNDULEAC, Ion TRIȘTIU, Ioan-Cătălin DAMIAN , Ionuț POPA, Paul LĂCĂTUȘ, Ștefan POPA , Marian PARASCHIV , Dorel STĂNESCU

Abstract

Rețelele electrice de joasa tensiune (JT) se caracterizează prin regimuri care sunt adeseori puternic nesimetrice, producând probleme legate de calitatea energiei electrice. Lucrarea prezintă rezultatele experimentale ale măsurării regimurilor nesimetrice pe un transformator stea-triunghi realizat la scara redusa, pe baza aplicării unor principii de similitudine si le compara cu analiza teoretică a funcționării in regim de nesimetrie a unor transformatoare de medie pe joasa tensiune (MT/JT). In acest scop se folosește un ansamblu trifazat de transformatoare la scara redusa, cu o putere totala de 8 kVA, care reprezintă un transformator MT/JT de 400 kVA, utilizând factori de similitudine adecvați, cum ar fi KSIMIL = 50 pe partea de joasă tensiune. Măsurătorile sunt realizate cu aparate de măsurare de înaltă calitate, respectiv cu un contor de energie electrica de precizie și cu un analizor de calitate, ambele fiind integrate într-un mic sistem SCADA cu care s-au realizat înregistrările. In lucrare se prezinta si adaptări specifice ale sistemului de măsurare, care sa permită o analiză in detaliu a regimurilor de funcționare pe ambele părți ale transformatorului steatriunghi. Scopul analizei este sa pună în evidență aspecte practice care sa facă o mai buna legătura intre modelul teoretic si experiența practică.

Low voltage (LV) networks are frequently operating with substantial unbalanced regimes, thus bringing power quality issues which need to be addressed. The present work presents experimental results of non-symmetric regimes on a reduced scale star-wye transformer, by applying principles of similitude, and compares the results versus a theoretical analysis of operation in a non-symmetrical regime of the MV/LV transformers. In this respect, a setup using a reduced scale transformer has been used, with a total power of 8 kVA, which is a reduced scale equipment of an 400 kVA MV/LV transformer, by using adequate similitude factors, such as KSIMIL = 50 for the current and power on the LV side. Measurements have been made with high quality devices, using a precision electronic smart meter of class 0.2S on one side and a power quality analyzer on the other side of the transformer, both being integrated in a small SCADA system which acquired and stored the necessary records. The work presents also specific adaptations of the measurement system in order to allow a detailed analysis of regimes of work on both sides of the star-wye transformer. The aim of the analysis is also to show practical aspects which can make a better link between theory and practice.

Keywords

unbalanced regimes, star-wye transformers, similitude, reduced scale, experimental results

Read the article

Contact

Headquarters
Lacul Tei Bvd. #1-3, sector 2, 020371, Bucharest

emerg@cnr-cme.ro
secretariat@cnr-cme.ro
+40 314 364 646
www.emerg.ro
ISSN 2668-7003
ISSN-L 2457-5011

See on Google Maps

© 2026 EMERG, All rights reserved.
seers cmp badge